SERSIO UNH requirements Power 450mA at +28V Flight Events 1) Rigid boom deploy 2) HV turn on above 160Km. The HV on function requires 28V at less than 20mA. Altitude switch hold-off of this function is not required. HV should be timed to turn on above 160Km and remain on. Umbilical A TEST signal is required. The TEST function requires 28V at 100mA. This line powers internal test oscillators for payload checks. Power to this line should come only from the umbilical so that there is no chance of the test oscillators being powered during flight. Telemetry requirements Signal Description type sample rate HEI HEEPS E image serial 16Khz HMI HEEPS M image serial 32Khz HT1I HEEPS T1 image serial 32Khz HT2I HEEPS T2 image serial 32Khz BPI BEEPS P image serial 4Khz BOI BEEPS O image serial 4Khz HET HEEPS E total counter 2Khz HMT HEEPS M total counter 2Khz HT1T HEEPS T1 total counter 2Khz HT2T HEEPS T2 total counter 2Khz BPT BEEPS P total counter 2Khz BOT BEEPS O total counter 2Khz HH1 HEEPS H pad 1 counter 2Khz HH2 HEEPS H pad 2 counter 2Khz HH3 HEEPS H pad 3 counter 2Khz HH4 HEEPS H pad 4 counter 2Khz TED1 TED1 counter 2Khz TED2 TED2 counter 2Khz HES HEEPS E sweep analog 250hz HHS HEEPS H sweep analog 250hz HMS HEEPS M sweep analog 250hz HT1S HEEPS T1 sweep analog 250hz HT2S HEEPS T2 sweep analog 250hz BS BEEPS sweep analog 250hz TS TED sweep analog 250hz TP TED skin potential analog 50hz HP HEEPS skin potential analog 50hz HEB HEEPS E bias analog 50hz HHB HEEPS H M T1 bias analog 50hz BB BEEPS HT2 bias analog 50hz TB TED bias analog 50hz HEC HE TED box current analog 50hz HHC HH HM HT1 box current analog 50hz BC BEEPS HT2 box current analog 50hz Total 1.2 Mbit Mechanical TED detector 3 X 1.5 X 1.5in. 1 lb. 2 triple detector cans. Each 9in by 3.5in dia. 3.5 lbs 3 electronics boxes. Each 6 X 6.6 X 3.5 in. 1.5 lbs. Total 12.5 lbs